News Updates Thursday 26th Dec 2024 :
  • Welcome to INPRESSCO, world's leading publishers, We have served more than 10000+ authors
  • Articles are invited in engineering, science, technology, management, industrial engg, biotechnology etc.
  • Paper submission is open. Submit online or at editor.ijcet@inpressco.com
  • Our journals are indexed in NAAS, University of Regensburg Germany, Google Scholar, Cross Ref etc.
  • DOI is given to all articles

The Modeling and Effect of FEM on Prosthetic limb


Author : Hasan Saad, Mohammad Qasim Abdullah and Hatem R. Wasmi

Pages : 892-895
Download PDF
Abstract

In this study, three dimensional Finite Element (FE) modeling of prosthetic lower limb was performed. A modified three dimensional finite element model of socket was developed in workbench of ANSYS 14.0 to find out the stress distribution and deformation pattern under functionally appropriate loading condition during normal gait cycle. This work tried to improve the deflection of the loading of Socket, foot, and pylon shank. The best designs results of the prosthetic above knee socket are (94.64%).In addition, a simplified stiffener has been added to optimize a moment of inertia of this main part thereby the deflection will be better, for this purpose a case study has been considered according to international standard for the Socket specification that investigated to illustrate the goal of this work . Moreover, the adopted design was selected carefully in order to match high strength and minimum weight criteria. Two types of FE analyses were performed; static analysis at standing position and dynamic analysis at jumping condition. The obtained results showed that the dynamic impact load is the most dominant since both materials were capable to stand with static load with minor Von Mises stresses acting on the pin connections. On the other hand, high Von Mises stresses were developed in the case of dynamic impact load which reached 90.19 MPa model. The results show that using stabilized method enables us to get stable and accurate numerical approximations consistent with the physical configuration of the problem over rough mesh by using ANSYS Workbench 14.0, AutoCAD and COMSOL 5.2. A high-density polyethylene (HDPE) was used for pylon.

Keywords: Prosthetic; Safety factor; Finite element model; Socket; pylon

Article published in International Journal of Current Engineering and Technology, Vol.7, No.3 (June-2017)

Call for Papers
  1. IJCET- Current Issue
  2. Issues are published in Feb, April, June, Aug, Oct and Dec
  3. DOI is given to all articles
  • Inpressco Google Scholar
  • Inpressco Science Central
  • Inpressco Global impact factor
  • Inpressco aap

International Press corporation is licensed under a Creative Commons Attribution-Non Commercial NoDerivs 3.0 Unported License
©2010-2023 INPRESSCO® All Rights Reserved